Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
PLoS One ; 17(12): e0279333, 2022.
Article in English | MEDLINE | ID: covidwho-2197086

ABSTRACT

BACKGROUND: The long-term cardiovascular (CV) outcomes of COVID-19 have not been fully explored. METHODS: This was an international, multicenter, retrospective cohort study conducted between February and December 2020. Consecutive patients ≥18 years who underwent a real-time reverse transcriptase-polymerase chain reaction (RT-PCR) for SARS-CoV2 were included. Patients were classified into two cohorts depending on the nasopharyngeal swab result and clinical status: confirmed COVID-19 (positive RT-PCR) and control (without suggestive symptoms and negative RT-PCR). Data were obtained from electronic records, and clinical follow-up was performed at 1-year. The primary outcome was CV death at 1-year. Secondary outcomes included arterial thrombotic events (ATE), venous thromboembolism (VTE), and serious cardiac arrhythmias. An independent clinical event committee adjudicated events. A Cox proportional hazards model adjusted for all baseline characteristics was used for comparing outcomes between groups. A prespecified landmark analysis was performed to assess events during the post-acute phase (31-365 days). RESULTS: A total of 4,427 patients were included: 3,578 (80.8%) in the COVID-19 and 849 (19.2%) control cohorts. At one year, there were no significant differences in the primary endpoint of CV death between the COVID-19 and control cohorts (1.4% vs. 0.8%; HRadj 1.28 [0.56-2.91]; p = 0.555), but there was a higher risk of all-cause death (17.8% vs. 4.0%; HRadj 2.82 [1.99-4.0]; p = 0.001). COVID-19 cohort had higher rates of ATE (2.5% vs. 0.8%, HRadj 2.26 [1.02-4.99]; p = 0.044), VTE (3.7% vs. 0.4%, HRadj 9.33 [2.93-29.70]; p = 0.001), and serious cardiac arrhythmias (2.5% vs. 0.6%, HRadj 3.37 [1.35-8.46]; p = 0.010). During the post-acute phase, there were no significant differences in CV death (0.6% vs. 0.7%; HRadj 0.67 [0.25-1.80]; p = 0.425), but there was a higher risk of deep vein thrombosis (0.6% vs. 0.0%; p = 0.028). Re-hospitalization rate was lower in the COVID-19 cohort compared to the control cohort (13.9% vs. 20.6%; p = 0.001). CONCLUSIONS: At 1-year, patients with COVID-19 experienced an increased risk of all-cause death and adverse CV events, including ATE, VTE, and serious cardiac arrhythmias, but not CV death. STUDY REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT04359927.


Subject(s)
COVID-19 , Thrombosis , Venous Thromboembolism , Humans , SARS-CoV-2 , Retrospective Studies , RNA, Viral , Registries
2.
Cardiovasc Revasc Med ; 32: 18-24, 2021 11.
Article in English | MEDLINE | ID: covidwho-1002377

ABSTRACT

OBJECTIVES: We sought to investigate stent healing and neointimal hyperplasia with ihtDEStiny drug-eluting stent (DES) by optical coherence tomography (OCT) examination conducted 9 months after implantation. BACKGROUND: The currently used DES present certain features that have been linked separately to their better performance in terms of efficacy and safety. METHODS: First-in-man, prospective and multicenter study including patients treated with ihtDEStiny stent undergoing OCT examination at 9 months follow up. The ihtDEStiny stent is a sirolimus eluting stent with an oval shape ultrathin struts (68 µm) and an abluminal coating of a fluoropolymer containing the antiplatelet agent triflusal. Primary endpoint was the percentage of obstruction of the in-stent volume by the neointima. RESULTS: In 58 patients (63 lesions) in-stent late lumen loss was 0.11 ± 0.23 mm (95% CI 0.05-0.16) with only in 6% of stents being > 0.5 mm and in-segment binary stenosis was 1.6%. In OCT mean neointima volume obstruction was 10.5 ± 6.9% with a mean neointima thickness of 110.9 ± 89.8 µm. The proportion of uncovered struts was 2.5%, malapposed struts 1.1% and malapposed/uncovered struts 0.7% and no subclinical thrombi detected. Mean incomplete stent apposition area was 0.1 ± 0.1 mm2. At 12 months target lesion revascularization rate was 3% and no stent thrombosis was reported. CONCLUSIONS: In this study the ihtDEStiny stent has shown a very low degree of neointimal proliferation associated with a low rate of uncovered/malapposed struts and total absence of subclinical thrombi at 9 months follow up.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Humans , Neointima , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Salicylates , Sirolimus/adverse effects , Stents , Tomography, Optical Coherence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL